Luminary Safety tester StandardIEC60598-1:2008 |
Product Name |
Main Technology Parameters |
Image |
MT98833D |
·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5.0uA—20.00mA(AC)/ 0.010μ A—10.00mA(DC) ·Insulation test voltage: (0.050-1.000)kV(DC)/. insulation resistance: 1MΩ -5.0 G Ω ·current output:(3.00~25.00)A(Constant current output) resistance test:(10.0~510.0 ) mΩ ·Pressure/grounding measurement precision:±(3%+3 counts) Insulation resistance measurement accuracy:±(5%+2 counts) |
|
MT99934D |
·withstand voltage: ( 0.500~5.000)kV(AC) (0.500~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·Ground: (3.00-30.00)A/ resistance test:(10.0~510.0 )mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA Leakage power basic configuration:1000VA ·power output voltage:(30.0—300.0)V/ current range:(0—5.000)A ·power range:(0—1000)VA |
|
MT99950B Programmable Lamps and lanterns grounding impedance tester MT95505D Leakage current Tester (lamps and lanterns) |
·current output:(5.0~25.0)A(Constant current output) · accuracy:±(2%+2 counts) ·resistance test:(10~500) mΩ(10A Current can test the resistance 500mΩ ) |
|
·output voltage:0~250V(adjustable)(AC) ·Isolation Transformer Capacity : 500VA ·leakage current range:10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to IEC 60598 Standard requirement of lamps and lanterns, four kinds of detection methods: effective value, average value, peak value ,DC |
|
MT95510D Leakage current Tester (lamps and lanterns) |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity : 1000VA ·leakage current range: 10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to IEC 60598 Standard requirement of lamps and lanterns, four kinds of detection methods: effective value, average value, peak value, DC |
|
MT95520D Leakage current Tester (lamps and lanterns) |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity :2000V ·leakage current range:10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to GB7000.1-2007 Standard requirement of lamps and lanterns, four kinds of detection methods: effective value, average value, peak value、DC |
|
MT95505E Leakage current Tester (lamps and lanterns) |
·output voltage:0~250V(adjustable)(AC) ·Isolation Transformer Capacity : 500VA ·leakage current range:10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to IEC60598-1:2008 Standard requirement of lamps and lanterns, four kinds methods: effective value, average value, peak value、DC |
|
MT95510E Leakage current Tester (lamps and lanterns) |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity : 1000VA ·leakage current range: 10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to IEC60598-1:2008 Standard requirement of lamps and lanterns, four kinds of detection methods: effective value, average value, peak value、DC |
|
MT95520E Leakage current Tester (lamps and lanterns) |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity :2000V ·leakage current range:10.0uA -20mA ·accuracy:±(2%+2 counts) ·conform to IEC60598-1:2008 Standard requirement of lamps and lanterns, four kinds of detection methods: effective value, average value, peak value、DC |
|