Medical Safety tester standard GB9706.1-2007 IEC601-1-1988

Medical Safety tester standard GB9706.1-2007 IEC601-1-1988 
Product Name Main Technology Parameters Image
MT99912YS  Programmable medical hipot tester (4.3 -inch color screen)  ·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC)     ·leakage current range:5.0uA—20.00mA(AC)/ 0.050μ A—10.00mA(DC)       ·accuracy:±(2%+2 counts)  ·With graphic oscilloscope interface
MT99914YS  Programmable medical hipot tester (4.3 -inch screen)  ·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC)     ·leakage current range:5.0uA—100.00mA(AC)/0.050μ A—50.00mA(DC)       ·accuracy:±(2%+2 counts)  ·With graphic oscilloscope interface 
MT99912Y  Programmable medical hipot tester  ·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC)     ·leakage current range:5.0uA—20.00mA(AC)/ 0.050μ A—10.00mA(DC)       ·accuracy:±(2%+2 counts)  With graphic oscilloscope interface 
MT99914Y  Programmable medical hipot tester  ·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC)     ·leakage current range:5.0uA—100.00mA(AC)/0.050μ A—50.00mA(DC)       ·accuracy:±(2%+2 counts)  ·With graphic oscilloscope interface of observation 
MT99950Y  Programmable grounding  resistance tester  ·current output:(5.00~30.00)A(Constant current output)   ·resistance test:(10.0~510.0 )mΩ             ·accuracy:±(2%+2 counts) 
MT95052Y  Programmable medical hipot tester  ·output voltage : (0.10-5.00)kV(AC)    ·Leakage Current Range:(0.100-20.00)mA        ·accuracy:±(2%+2 counts)  
MT95505F Medical leak tester  ·output voltage:0~250V(AC adjustable)     ·Isolation Transformer Capacity: 500VA    ·accuracy:±(2%+2 counts)              ·leakage current range:10.0uA~10.00mA(AC/DC)   
MT95510F Medical leak tester  ·output voltage:0~250V(AC adjustable)   ·Isolation Transformer Capacity: 1000VA    ·accuracy:±(2%+2 counts)                     ·leakage current range:10.0uA~10.00mA(AC/DC) 
MT95520F Medical leak tester  ·output voltage:0~250V(AC adjustable)     ·Isolation Transformer Capacity: 2000VA   ·accuracy:±(2%+2 counts)             ·leakage current range:10.0uA~10.00mA(AC/DC)   
MT95800Y  Medical grounding resistance tester  ·output current: (5.00~30.00)A        ·Grounding resistance test range:(10~600)mΩ           ·accuracy:±(2%+2 counts)           ·open circuit voltage is less than 6V    
MT70Y  Medical withstand voltage tester  ·voltage:0~5kV / current:0-20mA ·accuracy:±(5%+2 counts)  ·With graphic oscilloscope interface 
MT75FX Medical leak tester  ·output voltage : 0~250V±5%(adjustable) · time: 1~99s ·Isolation Transformer Capacity: 500VA   ·leakage current range: 0~200uA/0~2mA/2-10mA(AC)0~200uA+5%/0-2mA(DC) ·accuracy:±5% 
MT75FX-1 Medical leak tester  ·output voltage : 0~250V±5%(adjustable) · time: 1 ~99s ·Isolation Transformer Capacity: 1000VA   ·leakage current range: 0~200uA/0~2mA/2~10mA(AC)0~200uA+5%/0~2mA·accuracy:±5%  
MT75FX-2 Medical leakage current tester  ·output voltage : 0~250V±5%(adjustable) · time: 1 ~99s ·Isolation Transformer Capacity: 2000VA   ·leakage current range: 0~200uA/0~2mA/2~10mA(AC)0~200uA+5%/0~2mA(DC) ·accuracy:±5% 
MT75WF Passive medical three-phase  leakage current tester  ·output voltage : 0~400V±5%(adjustable)(AC)   ·leakage current range: 0~200uA+5%/0~2mA/2~10mA(continuation)(AC)  ·maximum test capacity: 20kVA   ·measurement accuracy:±5% 
MT78Y Full digital medical grounding resistance tester  ·output current: 5—30A   ·Grounding resistance test range 0—600mΩ         ·accuracy:±(5%+2 counts)