MT-E711 Xenon Lamp Test Chamber

Usage:
Xenon testing machine is to test the product undergone illumination/ rain/ condensation / temperature/ humidity/ wind and any other climatic changes. This aging tester is mainly for the test of non-ferrous/ organic/ rubber/ plastic and building materials. It can provide data for user to evaluate the products' properties and performance in order to improve the product qualities.

Design standard:

GB/T2423 24, GB/T16422.2, GB/T9344, GB/T1865, ISO 4892-3, ASTM G155-04a

Parameter:

• Studio size: 500 x 760 x 500mm (customized)
• Specimen holder:450*720mm (is adapted to the specimen with different shape)
• Light filter: 1
• Temperature range : RT- +80°C adjustable
• Humidity range: RT- + 80°C adjustable
• Temperature uniformity: ± 2°C
• Temperature fluctuation: ± 0.5°C
• Humidity deviation: ≤ ± 2%
• Temperature control: PID
• Xenon lamp number: 3
• Rainfall time: 0-9999min, continues rainfall adjustable
• Rainfall cycle: 0-240min, adjustable
• Nozzle diameter:Ø 8mm
• Distance from sample to lamp: 50mm
• Heating power: 2.0KW
• Humidification power : 1.5KW
• Distance from sample holder to sample : 300- 375mm
• Xenonlamp: 6KW ±10%
• Wavelength: 290-800nm
• lrradiance: 550-1500W/m2 adjustable
• specimen holder whirling speed : 1-5r/min
• Power: 1 , AC220V/50HZ, Max.11 KW

MT-E711 Xenon Lamp Test Chamber