Glow wire tester MLT-GW1

Product details:
This device is manufactured according to the standard of IEC60695-2-10, IEC60695-2-13. It also conforms to the standard requirement of UL746A. This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in s short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.

Test principle and products feature:
Test principle: the glowing filament whose material and shape is required(Ni80/Cr20)is heated to the testing temperature of 550 ℃~ 960 ℃ for 1 min by using the glow wire tester with large current. Then using required pressure (1.0N) vertically burns the test sample for 30s. By observing whether the test sample and bedding object ignite or the burning time, the users can judge the ignition danger of electric and electronic products. It is used for the ignition test, ignition temperature (GWIT) test, flammability test and flammability index (GWFI) test of solid insulating material and other solid combustible material.
Products feature: Adopting solenoid valve switch to control the burning depth of test sample and equipped with measuring gauge, this device has the features of exact and rapid. The test sample will break away automatically from glowing filament after reaching the set time. Adopting the original imported UK LAB K type armour ( 1mm ) whose temperature resistance is up to 1100° (exceed 1050°of standard requirement), this device is with accuracy temperature control.

Technical parameters:

Glowing filament Ф4mm ± 0.04mm Ni/Cr (77/20) special standard ring shape horizontal standing
Thermocouple 1mm import K thermocouple,the temperature resistance of armour is 1100 ℃ ( better than the standard of 1050 ℃ )
ohmic heating temperature of glowing filament 500 ℃~ 960 ℃ ( digital display can be preset Temperature fluctuation < 3 ℃
The accuracy of temperature measurement instrument is± 0.5 class.
Specimen pressure on glowing filament 0.95N±0.1N( adjustable )
Maximum depth of heating 7mm ± 0.5mm
Specimen movement speed 10mm /s ~ 25mm /s
Testing time 30s±0.1s(1s ~ 999.9s digital display preset )
Thickness of ignite bedding board thickness10mm, white pine board cover 12g /m2 ~ 30g /m2 standard silk paper  
Volume of test site ≥ 0.5m 3 black background, background illuminance ≤
20Lx, Volume of the cabinet, at least 0.5m3
Dimension and weight W: 1100mm × D: 550mm × H: 1200mm ,gasvent:100mm, 140kg
Control Touch screen display+PLC control
Power 1kVA 220V /50Hz& 110V /60Hz