Ground Resistance Tester | ||
Product Name | Main Technology Parameters | Image |
MT99950S Programmable grounding resistance tester | ·current output:(3.0~30.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10~510) mΩ | |
MT99950AS Programmable grounding resistance tester | ·current output:(3.0~25.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10~510) mΩ | |
MT99950CS Programmable grounding resistance tester | ·current output:(3.0~40.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10.0~510.0) mΩ | |
MT99950 Programmable grounding resistance tester | ·current output:(5.0~30.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10~510) mΩ | |
MT99950A Programmable grounding resistance tester | ·current output:(5.0~25.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10~510) mΩ | |
MT99950CX Programmable grounding resistance tester | ·current output:(3.0~40.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10.0~510.0) mΩ | |
MT99950D Programmable grounding resistance tester | ·current output:(3.0~60.0)A(Constant current output) accuracy:±(2%+2 counts) ·resistance test:(10~510) mΩ | |
MT99950E Programmable DC grounding resistance tester | ·current output:1.00A~30.00A(DC) ·resolution:0.01A ·accuracy:± (0.5%+0.01A) ·Resistance setting range:(1.0~600.0)m Ω ·resolution:0.1m Ω ·timer:0.0s~999.9s | |
MT99950EA Programmable DC grounding resistance tester | ·current output:1.00A~40.00A(DC) ·resolution:0.01A ·accuracy:± (0.5%+0.01A) ·Resistance setting range:(1.0~600.0) mΩ ·resolution:0.1mΩ ·timer:0.0s~999.9s | |
MT99950EC Programmable DC grounding resistance tester | ·current output:1.00A~60.00A(DC) ·resolution:0.01A ·accuracy:± (0.5%+0.02A) ·Resistance setting range:(1.0~600.0) mΩ ·resolution:0.1mΩ ·timer:0.0s~999.9s | |
MT95800 Programmable grounding resistance tester | ·current output: (5.00~30.00)A/grounding resistance test range:(10~600)mW ·accuracy:±(2%+2 counts) ·Open circuit voltage is less than 12V | |
MT95800A Programmable grounding resistance tester | ·current output: (5.00~42.00)A/ grounding resistance test range:(10~600)mΩ ·accuracy:±(2%+2 counts) ·Open circuit voltage is less than 12V | |
MT78X Full digital display grounding resistance tester | ·current output: (5—30)A ·grounding resistance test range 0—600mΩ accuracy:±(5%+2 counts) | |
MT78N Full digital display grounding resistance tester | ·current output: (5—32)A ·grounding resistance test range 0—600mΩ accuracy:±(5%+2 counts) |