Insulation /Withstand Voltage Tester 999S series

Insulation /withstand voltage tester
999S series color screen programmable hipot tester 
Product Name Main Technology Parameters Image
MT99922S Programmable Insulation Resistance Tester  ·output voltage: (0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5μ A—15.00mA(AC)/ 0.050μ A—5.00mA(DC)     ·Insulation test voltage: (0.250-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ?     ·Pressure measurement precision:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts) 
MT99922BS  programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC) / (0.050-6.000)kV(DC)       ·leakage current range:5μ A—20.00mA(AC)/ 0.050μ A—10.00mA(DC)   ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ?   ·withstanding voltage accuracy:±(2%+2 counts) ·Insulation resistance measurement accuracy:±(5%+2 counts)   
     
MT99922CS  programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC)  ·leakage current range:5μ A—20.00mA(AC)   ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ?    ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts)   
MT99922DS  programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC)/ (0.050-6.000)kV(DC)       ·leakage current range:5μ A—50.00mA(AC)/ 0.050μ A—20.00mA(DC)   ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ?    ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts)   
MT99922ES programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC)      ·leakage current range:5μ A—100.00mA(AC)/ 0.050μ A—50.00mA(DC)   ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ?     ·withstanding voltage accuracy:±(2%+2 counts),Insulation resistance measurement accuracy:±(5%+2 counts)   
MT99922FS  programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC)/ (0.050-6.000)kV(DC)      ·leakage current range:5μ A—100.00mA(AC)/ 0.050μ A—50.00mA(DC)  ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -50.0G ?     ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts)   
MT99922HS  programmable Insulation  Resistance hipot Tester  ·output voltage:(0.050-5.000)kV(AC)    accuracy:±(2%+2 counts) ·leakage current range:5μ A—20.00mA(AC) accuracy:±(2%+2 counts) ·Insulation test voltage: (0.050-1.000)kV(DC) · insulation resistance: 1M ? -99.999 G ?    ·accuracy:±(5%+2 counts)