Insulation /withstand voltage tester 999S series color screen programmable hipot tester |
||
Product Name | Main Technology Parameters | Image |
MT99922S Programmable Insulation Resistance Tester | ·output voltage: (0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5μ A—15.00mA(AC)/ 0.050μ A—5.00mA(DC) ·Insulation test voltage: (0.250-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ? ·Pressure measurement precision:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922BS programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC) / (0.050-6.000)kV(DC) ·leakage current range:5μ A—20.00mA(AC)/ 0.050μ A—10.00mA(DC) ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ? ·withstanding voltage accuracy:±(2%+2 counts) ·Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922CS programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC) ·leakage current range:5μ A—20.00mA(AC) ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ? ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922DS programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC)/ (0.050-6.000)kV(DC) ·leakage current range:5μ A—50.00mA(AC)/ 0.050μ A—20.00mA(DC) ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ? ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922ES programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5μ A—100.00mA(AC)/ 0.050μ A—50.00mA(DC) ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -10.0 G ? ·withstanding voltage accuracy:±(2%+2 counts),Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922FS programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC)/ (0.050-6.000)kV(DC) ·leakage current range:5μ A—100.00mA(AC)/ 0.050μ A—50.00mA(DC) ·Insulation test voltage: (0.050-1.000)kV(DC) ·insulation resistance: 1M ? -50.0G ? ·withstanding voltage accuracy:±(2%+2 counts) · Insulation resistance measurement accuracy:±(5%+2 counts) | |
MT99922HS programmable Insulation Resistance hipot Tester | ·output voltage:(0.050-5.000)kV(AC) accuracy:±(2%+2 counts) ·leakage current range:5μ A—20.00mA(AC) accuracy:±(2%+2 counts) ·Insulation test voltage: (0.050-1.000)kV(DC) · insulation resistance: 1M ? -99.999 G ? ·accuracy:±(5%+2 counts) |