Temperature Rise Tester MLT-TR1

The device is made and manufactured according to the related standard requirement of temperature rising, such as IEC 60884-1 (Figure 44), VDE 0620 etc. It is applicable to the temperature rising of electronic accessories in working position.

Technical parameters:

Item Name MLT-TR-1 MLT-TR-2 MLT-TR-3
Working station 6 6 6
Testing current 0-40A 0-125A 50-1000A adjustable
Testing voltage <12V <12V 5V,12V,24V,48V
Timer 0-9999s  adjustable, digital display 0-9999s  adjustable, digital display 0-9999s  adjustable, digital display
Temperature measurement table 0-150°digital display 0-150°digital display 0-150°digital display
Power supply 220V,50HZ 220V,50HZ 220V,50HZ
standard IEC 60884-1 GB13140.1 UL
Test object Plug pin connector circuit board


- When the current exceeds the required value, the device stops working automatically. The range of the alarm is from 0 to the maximum current. The overcurrent time can be recorderd automatically.
- When the temperature exceeds the required value, the device stops working automatically. The range of the alarm is from 0 to 150℃. The overtemperature time is recorderd automatically.

 

Temperature Rise Tester MLT-TR1