Comprehensive safety tester withstanding voltage,insulation 、grounding, leakage, power, low voltage startup |
Product Name |
Main Technology Parameters |
Image |
MT99949 Programmable safety comprehensive tester (high voltage, insulation and grounding, leakage, power, low voltage start) |
·withstand voltage: (0.050~5.000)kV(AC) (0. 050~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.050~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: 3.00-30.00A/ resistance test:(10.0~510.0 )mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA/ Leakage power basic configuration:300VA ·power output voltage:(30.0—300.0)V/ current range:(0—5.000)A/ power range:(0—300)VA ·Low voltage start output voltage:(30.0—300.0)V ·current range:(0—5.000)A |
|
MT99949A Programmable safety comprehensive tester (high voltage, insulation and grounding, leakage, power, low voltage start) |
·withstand voltage: (0.050~5.000)kV(AC) (0. 050~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.050~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: 3.00-30.00A/ resistance test:(10.0~510.0 )mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA/ Leakage power basic configuration:1000VA ·power output voltage:(30.0—300.0)V/ current range:(0—5.00)A ·power range:(0—1000)VA ·Low voltage start output voltage:(30.0—300.0)V . current range:(0—5.00)A |
|
MT99949X safety comprehensive tester (high voltage, insulation and grounding, leakage, power, low voltage start, with variable frequency power supply, cabinet) |
·withstand voltage: (0.050~5.000)kV(AC) (0. 050~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.050~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: 3.00-30.00A/ resistance test:(10.0~510.0 )mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA .Leakage power basic configuration:3000VA ·power output voltage:(30.0—300.0)V/ current range:(0—10.00)A/ power range:(0—3000)VA ·Low voltage start output voltage:(30.0—300.0)V ·current range:(0—10.00)A |
|
MT99946 Programmable safety comprehensive tester (combination of seven) |
·withstand voltage: ( 0.500~5.000)kV(AC) (0.500~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.100~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: (3.00-30.00)A/ resistance test:(10.0~510.0 ) mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA ·Leakage power basic configuration:300VA ·power output voltage:(30.0—300.0)V/ current range:(0—5.000)A ·power range:(0—300)VA ·Low voltage start output voltage:(30.0—300.0)V · current range:(0—5.000)A |
|
MT99946A Programmable safety comprehensive tester (combination of seven) |
·withstand voltage: ( 0.500~5.000)kV(AC) (0.500~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.100~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: (3.00-30.00)A/ resistance test:(10.0~510.0 ) mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA ·Leakage power basic configuration:1000VA ·power output voltage:(30.0—300.0)V/ current range:(0—5.000)A power range:(0—1000)VA ·Low voltage start output voltage:(30.0—300.0)V . current range:(0—5.000)A |
|
MT99946X Programmable safety comprehensive tester (combination of seven) |
·withstand voltage: ( 0.500~5.000)kV(AC) (0.500~6.000)kV(DC) ·current range:(0.01~40.00)mA(AC) (0.001~20.00)mA(DC) ·insulation: (0.100~1.000)kV(DC)/ insulation resistance:(1~9999)MΩ ·ground: (3.00-30.00)A/ resistance test:(10.0~510.0 ) mΩ ·leakage:(30.0~300.0)V/ leakage current:0.1uA~20mA · Leakage power basic configuration:3000VA ·power output voltage:(30.0—300.0)V ·current range:(0—10.00)A/ power range:(0—3000)VA ·Low voltage start output voltage:(30.0—300.0)V ·current range:(0—10.00)A |
|