Hipot Tester 999X programmable hipot tester | |||||
- Automatic rise voltage - Arc detection - low distortion - English interface switching - GFI function- Real current - High voltage - Set current upper and - Keypad lock- Gradient rise - Unqualified audible and visual alarm - offset function lower limits - Grounding / floating ground mode- maintained high voltage breakdown - High pressure la breakdown protection - Leakage current and testing time continuous setting - 50 remembered group , 40 test step- 0.2 Seconds fast discharge function-Test result list saved - AC minimum resolution 0.1μ A,D C minimum resolution 0.001μ A - standard equipped PLC Interface RS232, Optional \USB\485 Interface | |||||
Product Name | Main Technology Parameters | Image | |||
MT99912BX Programmable precision withstanding voltage tester | ·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC)·leakage current range:5.0uA—20.00mA(AC)/ 0.050μ A—10.00mA(DC)· accuracy:±(2%+2 counts) | ||||
MT99913AX Programmable precision withstanding voltage tester | ·output voltage:(0.050-5.000)kV(AC) ·leakage current range:5.0uA—50.00mA(AC) ·accuracy:±(2%+2 counts) | ||||
MT99913BX Programmable precision withstanding voltage tester | ·output voltage:(0.050-5.000)kV(AC)/ (0.050-6.000)kV(DC) ·leakage current range:5.0uA—50.00mA(AC)/ 0.050μ A—20.00mA(DC) ·accuracy:±(2%+2 counts | ||||
MT99914AX Programmable precision withstanding voltage tester | ·output voltage:(0.050-5.000)kV(AC) ·leakage current range:5.0uA—100.00mA(AC) ·accuracy:±(2%+2 counts) | ||||
MT99914BX Programmable precision withstanding voltage tester | ·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC)·leakage current range:5.0uA—100.00mA(AC)/ 0.050μ A—50.00mA(DC) · accuracy:±(2%+2 counts) | ||||
MT99915AX Programmable ultra-high voltage tester | ·output voltage: (0.500-9.999)kV(AC) adjustable accuracy:±(2%+2 counts) ·leakage current range:(0.100 -10.00)mA(AC) accuracy:±(2%+2 counts) | ||||
MT99916AX Programmable ultra-high voltage tester | ·output voltage: (0.500-9.999)kV(AC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -20.00)mA(AC) accuracy:±(2%+2 counts) | ||||
MT99916BX Programmable ultra-high voltage tester | ·output voltage: (0.500-9.999)kV(DC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -10.00)mA(DC) accuracy:±(2%+2 counts) | ||||
MT99917AX Programmable ultra-high voltage tester | ·output voltage: (0.500-9.999)kV(AC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -50.00)mA(AC) accuracy:±(2%+2 counts) | ||||
MT99917BX Programmable ultra-high voltage tester | ·output voltage: (0.500-9.999)kV(DC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -20.00)mA(DC) accuracy:±(2%+2 counts) | ||||
MT99920A Programmable ultra-high voltage tester | ·output voltage: (0.500-20.00)kV(AC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -10.00)mA(AC) accuracy:±(2%+2 counts) | ||||
MT99920B Programmable ultra-high voltage tester | ·output voltage: (0.500-20.00)kV(DC) accuracy:±(2%+2 counts) ·leakage current range:(0.100 -10.00)mA(DC) accuracy:±(2%+2 counts) |