Medical Safety tester standard GB9706.1-2007 IEC601-1-1988 |
Product Name |
Main Technology Parameters |
Image |
MT99912YS Programmable medical hipot tester (4.3 -inch color screen) |
·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC) ·leakage current range:5.0uA—20.00mA(AC)/ 0.050μ A—10.00mA(DC) ·accuracy:±(2%+2 counts) ·With graphic oscilloscope interface |
|
MT99914YS Programmable medical hipot tester (4.3 -inch screen) |
·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5.0uA—100.00mA(AC)/0.050μ A—50.00mA(DC) ·accuracy:±(2%+2 counts) ·With graphic oscilloscope interface |
|
MT99912Y Programmable medical hipot tester |
·output voltage:(0.050-5.000)kV(AC)/(0.050-6.000)kV(DC) ·leakage current range:5.0uA—20.00mA(AC)/ 0.050μ A—10.00mA(DC) ·accuracy:±(2%+2 counts) With graphic oscilloscope interface |
|
MT99914Y Programmable medical hipot tester |
·output voltage:(0.050-5.000)kV(AC) /(0.050-6.000)kV(DC) ·leakage current range:5.0uA—100.00mA(AC)/0.050μ A—50.00mA(DC) ·accuracy:±(2%+2 counts) ·With graphic oscilloscope interface of observation |
|
MT99950Y Programmable grounding resistance tester |
·current output:(5.00~30.00)A(Constant current output) ·resistance test:(10.0~510.0 )mΩ ·accuracy:±(2%+2 counts) |
|
MT95052Y Programmable medical hipot tester |
·output voltage : (0.10-5.00)kV(AC) ·Leakage Current Range:(0.100-20.00)mA ·accuracy:±(2%+2 counts) |
|
MT95505F Medical leak tester |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity: 500VA ·accuracy:±(2%+2 counts) ·leakage current range:10.0uA~10.00mA(AC/DC) |
|
MT95510F Medical leak tester |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity: 1000VA ·accuracy:±(2%+2 counts) ·leakage current range:10.0uA~10.00mA(AC/DC) |
|
MT95520F Medical leak tester |
·output voltage:0~250V(AC adjustable) ·Isolation Transformer Capacity: 2000VA ·accuracy:±(2%+2 counts) ·leakage current range:10.0uA~10.00mA(AC/DC) |
|
MT95800Y Medical grounding resistance tester |
·output current: (5.00~30.00)A ·Grounding resistance test range:(10~600)mΩ ·accuracy:±(2%+2 counts) ·open circuit voltage is less than 6V |
|
MT70Y Medical withstand voltage tester |
·voltage:0~5kV / current:0-20mA ·accuracy:±(5%+2 counts) ·With graphic oscilloscope interface |
|
MT75FX Medical leak tester |
·output voltage : 0~250V±5%(adjustable) · time: 1~99s ·Isolation Transformer Capacity: 500VA ·leakage current range: 0~200uA/0~2mA/2-10mA(AC)0~200uA+5%/0-2mA(DC) ·accuracy:±5% |
|
MT75FX-1 Medical leak tester |
·output voltage : 0~250V±5%(adjustable) · time: 1 ~99s ·Isolation Transformer Capacity: 1000VA ·leakage current range: 0~200uA/0~2mA/2~10mA(AC)0~200uA+5%/0~2mA·accuracy:±5% |
|
MT75FX-2 Medical leakage current tester |
·output voltage : 0~250V±5%(adjustable) · time: 1 ~99s ·Isolation Transformer Capacity: 2000VA ·leakage current range: 0~200uA/0~2mA/2~10mA(AC)0~200uA+5%/0~2mA(DC) ·accuracy:±5% |
|
MT75WF Passive medical three-phase leakage current tester |
·output voltage : 0~400V±5%(adjustable)(AC) ·leakage current range: 0~200uA+5%/0~2mA/2~10mA(continuation)(AC) ·maximum test capacity: 20kVA ·measurement accuracy:±5% |
|
MT78Y Full digital medical grounding resistance tester |
·output current: 5—30A ·Grounding resistance test range 0—600mΩ ·accuracy:±(5%+2 counts) |
|